Keysight N9030A PXA signal analyzer is the highest-performance member of the Keysight X-Series signal analyzers and is the evolutionary replacement for your current performance signal analyzer. It provides frequency coverage up to 26.5 GHz and ensures present and future flexibility through optional measurement capabilities and hardware expandability.
The PXA’s advanced performance, flexibility, capability, and expandability enable you to address demanding aerospace, defense, and commercial communications applications. In addition, the PXA includes extensive remote language compatibility features that make it easier to replace existing Agilent performance spectrum analyzers.
As the flagship of the X-Series signal analyzers, the Keysight N9030A PXA signal analyzer delivers exceptional performance that reduces measurement uncertainty and reveals new levels of signal detail, starting with up to 75 dB spurious-free dynamic range at the 140-MHz analysis bandwidth. Industry-leading specifications include –129 dBc/Hz phase noise at 10 kHz offset (1 GHz), ±0.19 dB absolute amplitude accuracy, and sensitivity of –172 dBm displayed average noise level (DANL) at 2 GHz (with preamplifier and Noise Floor Extension technology).
The X-Series is an evolutionary approach to signal analysis that spans instrumentation, measurements, and software. It allows you to satisfy your business and technical requirements across multiple products and programs now – and in the future.
Keysight N9030A PXA high-performance X-Series signal analyzer up to 50 GHz (to 325 GHz and beyond with external mixer) ideal for applications in A/D, commercial communications, and more; remote language compatibility; real-time spectrum analyzer capabilities.
Features and Specifications of the Keysight N9030A PXA Signal Analyzer include:
Functionality:
- 3 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
- 10 MHz (standard), 25, 40, or 140 MHz analysis bandwidth
- 12 markers, marker table, and simultaneous detectors
- Configuration choices for PXA instrument hardware
Performance:
- ±0.19 dB absolute amplitude accuracy
- +21 dBm third order intercept (TOI) at 2 GHz
- -172 dBm displayed average noise level (DANL)
- -83 (-88 dBc nominal) W-CDMA ACLR dynamic range (with noise correction on)
Measurement Applications & Software:
- Phase noise, noise figure, LTE, W-CDMA/HSPA/HSPA+, analog demodulation, digital video, and more. X-Series advanced measurement applications
- Advanced analysis of more than 70 signal formats; software runs inside the PXA. 89600 VSA software
- MATLAB® data analysis software for general purpose data analysis, visualization, and measurement automation. MATLAB software for the X-Series
Automation & Communication Interface:
- LXI class C compliant, SCPI and IVI-COM
- USB 2.0, 1000Base-T LAN, GPIB
- Programming remote language compatibility with PSA, 8566/68, and 856x
- Common X-Series user interface/Open Windows® XP operating system
Options
- 0BW – Hard Copy Assembly-Level Service Guide
- 1A7 – ISO 17025 accredited calibration
- 1CM – Rack mount kit
- 1CN – Front handle kit
- 1CP – Rackmount and handle kit
- 1CR – Rack slide kit
- 503 – Frequency range, 3 Hz to 3.6 GHz
- 508 – Frequency range, 3 Hz to 8.4 GHz
- 513 – Frequency range, 3 Hz to 13.6 GHz
- 526 – Frequency range, 3 Hz to 26.5 GHz
- 543 – Frequency range, 3 Hz to 43 GHz
- 544 – Frequency range, 3 Hz to 44 GHz
- 550 – Frequency range, 3 Hz to 50 GHz
- A6J – ANSI Z540 compliant calibration
- AB2 – Hard Copy of X-Series Chinese Getting Started and Troubleshooting Guide
- ALV – Auxiliary log video output
- B1X – Analysis Bandwidth, 160 MHz
- B25 – N9030A-B25 Analysis bandwidth
- B40 – Analysis bandwidth, 40 MHz
- BBA – I/Q baseband inputs, analog
- C35 – APC 3.5 mm connector
- CR3 – Connector Rear, Wideband IF output
- CRP – Connector Rear, Programmable IF output
- DVR – DVD – ROM/CD-R/RW drive
- EA3 – Electronic attenuator, 3.6 GHz
- EDP – Enhanced display package
- EMC – Basic EMC Functionality
- ESC – External source control
- EXM – External mixing
- KB2 – US 65 key USB keyboard
- KYB – USB Keyboard
- LNP – Low noise path
- MLP – Minimum loss pad, 50 to 75 ohm
- MPB – Microwave preselector bypass
- P03 – Preamplifier, 3.6 GHz
- P08 – Preamplifier, 8.4 GHz
- P50 – Preamplifier, 50 GHz
- SSD – Additional removable solid state drive
- UK6 – Commercial calibration test data
- YAV – Y-axis video output
Additional Services
- fresh Calibration
- Calibration plans
- KeysightCare Assured (includes Keysight Extended Warranty)
Include:
- Signal analyzer,
- spectrum analysis measurement application,
- high-performance single-core processor / 4 GB RAM / removable solid-state hard drive,
- fine attenuation mechanical attenuator,
- 10 MHz demodulation bandwidth,
- 2 GB DSP with memory,
- improved phase noise performance,
- fast sweep function,
- LO leakage, internal intermodulation elimination, lower band extension, noise reduction, precision reference oscillator,
- Windows Embedded Standard 7,
- real-time data link (40 MHz bandwidth),
- mouse, keyboard, user manual, front panel protective cover, power cable,
- 3-year warranty
Reference Library