Midmark Ritter M11 Ultraclave Automatic Autoclave Sterilizer has an intuitive display and simple prompts help that you easily select the cycle you need whether it is for unwrapped items, pouches, packs or handpiece
Features include:
Midmark has designed the M11 with features that have benefits which are directly obvious to the operator or practice manager. One of the most important is the automatic opening door on Ultraclave models.
By having the door open automatically at the end of the cycle, the most obvious benefit is that the unit is now in the dry mode and to alert the operator that the current sterilizing cycle is over.Large 11″ by 18″ chamber for increased load capacity
For most operational needs, the user needs only to push two buttons to begin a sterilizing cycle. After loading the materials and closing the door, the operator simply pushes one key to select one of the common cycles and a second button starts the operation. No further operator interaction is needed.
Single button controls allow quick sterlizing of items by using of the four defined cycles: “Unwrapped.”, “Pouches,”, “Packs”, or “Handpieces.” Each of these has a specific sterilizing temperature, time, venting type and drying time established as follows: Unwrapped (132º C or 270º F for 3 minutes), Pouched (132º C or 270º F for 5 minutes), Packs (121º C or 250º F for 30 minutes), Handpieces. The cycle is begun by pressing the “start” button.
Bright Green LCD Display for easy view of indicators. Indicates cycle selected, temperature and exposure time for selected cycle. During the cycle, the display shows messages describing status of cycle. When the cycle enters sterilization mode, remaining time is displayed as well as temperature and pressure.
Self Programmable Digital Control
Programmable controls allow for creation of various different cycle parameters to meet your unique sterilization needs. Change the following:
- Time (3 to 90 minutes),
- Temperature (230 to 275°F),
- Dry Time (0 to 60 minutes),
- Vent (slow or fast) and two
- program buttons. The #1 and
- #2 buttons allow you to store the change if desired for future use.
Cycle Start
(Initiates selected cycle)
Manual Stop
(Terminates selected cycle or function)
Warranty
One full year on site parts and labor
Specifications
Footprint:
Overall length w/plug: 23.8″ (60.5 cm)
Overall width: 17.8″ (45.2 cm)
Overall height w/printer: 17.8″ (45.2 cm)
Minimum Countertop area: 17.8″ x 21.0″ (45.2 x 53.3 cm)
Chamber Size:
11″ diameter (28 cm)
18″ depth (45.7 cm)
6.5 gal. usable volume (24.6 liters)
Tray Information:
Two large trays – 9″ W x 15″ L x 1.1″ D
(22.9 cm x 38 cm x 2.9 cm)
Two small trays – 6.6″ W x 15″ L x 1.1″ D
(16.8 cm x 38 cm x 2.9 cm)
Unit actual eight: 99 lbs. (44.9 kg)
Shipping weight with pallet – 131 lbs. (59.4 kg)
Water holding reservoir capacity: 1.4 gal. (5.3 liters)
Electrical Requirements
115 VAC, 50/60 Hz, 15 Amps, Single Phase
115 VAC has 1425 watt tubular immersion heater
UL61010A-1, UL61010A-2-041
CAN/CSA C22.2 No. 1010
CAN/CSA C22.2 No. 1010.2-041-96
For more information : http://www.tigermedical.com/files/872907a4-d004-49c5-82bf-d9a3062a9a15m11%20manual.pdf